Extractor Fan Venting Into Attic

The best exhaust fan venting is through smooth rigid ducts with taped joints and screwed to a special vent hood.
Extractor fan venting into attic. In order to accomplish this the roof has to have a hole cut in it. Attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents. Historically extractor fans were vented into the attic of the home. A grille in each bathroom attaches to ducts which then fasten to a y connector at the fan.
Bathroom exhaust fans perform an important function by removing excess moisture from your home. Roof is hipped so unfortunately gable wall is not an option. Through the roof depending on the location of the bathroom it may be easy to vent the exhaust fan through the roof. A bath vent fan duct that is too short may violate the manufacturer s installation instructions may not work properly or may be drafty.
When venting a bathroom exhaust fan make sure to vent the air to the outside rather than into your attic where it can cause mold and mildew to form. For this to work properly air ducts must be properly sealed meaning no tears or holes that would allow moisture to escape into the wrong spots. Although this isn t always possible in attic crawl spaces you should always insulate the duct to prevent condensation problems. Home builders learned from this lesson and began running exhaust ventilation ducts to the outside of the home.
Here we provide specifications for recommended minimum maximum duct lengths for bathroom vent fans. Your attic is not a temperature controlled environment is never the same temperature as your living space and generally closer to the temperature outside. No you cannot vent your bathroom exhaust fan into the attic. Options for venting a bathroom exhaust fan include best to worst.
But while you can t have two fans with one vent you can make one fan and one vent serve two bathrooms. Guys you could get a hole bored on your gable wall from the attic through too the outside ther are companies who specialise in hole boring get out the yellow pages then connect the extractor and the hole with a flexi hose. Intake vents located at the lowest part of the roof under the eaves allow cool. This involves running ductwork from the fan usually though an attic and out through the roof.
This setup requires an in line centrifugal fan mounted in the attic drawing air simultaneously from both bathrooms see photo. Duct already wrapped in insulation at home centers. You should never exhaust the bathroom fan directly into the attic.