Fire Rated Electrical Box Pads

Specseal ssp firestop putty excels at sealing cabling penetrations and outlet boxes.
Fire rated electrical box pads. Item fire barrier putty. Designed to prevent the spread of fire smoke and noxious gasses this intumescent material comes ready to use in convenient 1 10 2 54 mm thick pads that are conformable by hand with no mixing or tools. When applied with outlet boxes ssp putty easily works into voids and seams forming a continuous seal against fire and the products of combustion. Provides up to 4 hours of fire protection.
4 1 out of 5 stars 4. A one part ready to use re enterable intumescent putty that can be easily formed to firestop wall openings and through penetrations in fire rated assemblies. There are also putty pads known in industry as gaskets available for application under the wiring device cover plate. 1 16 of 224 results for putty pads for electrical boxes did you mean potty pads for electrical boxes specseal ssp putty pads case of 20 7 1 4 square.
Get it as soon as thu oct 8. These stick play dough like pads are installed to the back of an electrical outlet to provide proper fire stopping to the outlet penetration. Metacaulk putty pads are used to maintain the hourly rating of fire rated walls containing electrical outlet boxes and to reduce sound transmission. Metacaulk fire rated putty pads.
4 inch x 8 inch dark red moldable pad 101 6 mm x 203 2 mm. Ul classified putty pads also known in industry as box inserts are for installation on the inside back surface of the box. Most non metallic electrical boxes certified for use in fire rated walls require 24 horizontal separation between boxes on opposite sides of a wall if they are not protected with putty pads. Only one pad thickness 1 8 inch is required for a 1 or 2 hour fire rating.
Firestop application cables ducts insulated pipe metal pipe. View full product list 3 features applications. Intumescent box insert designed to help protect electrical outlet boxes from fire and smoke. Fire rating up to 4 hr.
For approval or certificate information please see individual items. Ssp putty is non hardening and easily hand works around grouped cabling penetrations forming a re enterable seal allowing for future work. Unfortunately these pads are limited to new construction as the wall cavity must be open to install properly. Standards ul classified and fm approved.
Rectorseal 66335 7 inch by 7 inch by 1 8 inch metacaulk fire rated putty pads. 4 5 out of.