Flat Roof Insulation Between Rafters

The old roof was tar and gravel so the switch to tpo should show significant change.
Flat roof insulation between rafters. To protect the roof from the potential of condensation occurring unseen within the construction it s important to remember that the layer of insulation installed over the rafters should as general rule be double the thickness of the insulation layer between the rafters. Also there is a soffit vent but none at roof peak. I have an insulation factor of about 8 10 plus the reflectivity of the white tpo. Pitched roof rafter level.
It allows insulation to be installed in a watertight roof either after the roof covering has been fixed on a new build or without disturbing an otherwise sound existing roof covering as part of a renovation. Kingspan with a flat roof this issue does not arise but the u value constraint and the amount of insulation needed is just the same. On new build or replacement pitched roofs the ideal build up would be insulation fitted over and then between the rafters giving a big boost for airtightness image credit. The general advice we give is that you should always insulate between and above the rafters or between and under the rafters on our u value calculator we don t give an option for putting insulation between the rafters.
The underside of the rafters in this case will need to be finished with a suitable vapour control layer vcl and plasterboard to provide a suitable internal finish to the roof. A warm deck roof is where the insulation is placed on top of the rafters joists and the roof covering is then placed over the insulation. The insulation is below the deck but above the plasterboard. Cold deck roof a cold deck roof is where the insulation is placed between the joists rafters or in between the ceiling joists in the case of a pitch roof.
An over and between rafter insulation solution can be a feature of a. This is used for refurbishment e g. In this blog post we will be looking at insulating pitched roofs and why putting insulation just between the rafters isn t a viable solution. Breathing roof with low resistance lr underlay with this option insulation fully fills the rafter space without an airspace between the insulation and type lr underlay.
Should i leave out the soffit vent. No ventilation is required for these types of roofs. Where the insulation does not fill the total rafter depth the low emissivity foil facings can gain additional thermal benefit from the air spaces they face. Is there any advantage to trying to get any insulation in between the 2 8 rafters.
Modern u value targets mean installing insulation between rafters only is rarely a viable option. Once up at roof level the between rafter boards can be cut accurately to fit the rafter spacings. Being lightweight they do not impose significant additional loads on existing structures. Insulation between the rafters can be designed in two ways.